Clocks and collecting punches
The time clocks connected to this computer by a serial (COM) port. Click Collect to read the punches now; the clocks marked Auto collect are read at the times set in Settings.
The Clocks screen lists the time clocks (Verifone Tranz 380) connected by cable to the computer where PunchPlus Web runs, and reads (collects) their punches. Each punch is saved to the database and to an archive file before the clock is told it can forget it, so no punch is lost if the connection breaks.
On this screen
Serial ports on this computer
This panel shows the COM ports PunchPlus Web finds on the computer: for each one, its name (for example COM3), its description (for example USB Serial Port) and whether it is used by a clock or free. Click Check again after plugging in a cable or a USB adapter.
| Message | What it means |
|---|---|
| A note saying PunchPlus Web is open from another computer | You are using PunchPlus Web through the internet (for example punch.inforap.com) or from another computer. The server cannot see the ports of the computer in front of you, so they show as Cannot check. You can still choose the port of a clock. |
| A note saying the program runs on a computer without COM ports | PunchPlus Web runs on a server. The clocks are read on the store computer. |
| No serial port found. Check the cable or the USB adapter. | The computer has no COM port right now. |
| The serial ports cannot be listed on this computer. | The ports cannot be checked here. |
The list of clocks
| Column | What it shows |
|---|---|
| Br. | The branch of the clock. Its punches are matched with the employees of this branch. |
| Location | Where the clock is, for example Front entrance (click it to open its settings). |
| Description | More about the clock, with its speed, parity, data/stop bits and delay under it. |
| Port | The COM port. |
| Port status | Connected (the port exists on this computer), Not found or Cannot check. |
| Auto collect | A check mark when the clock is read automatically. |
| Collect | Reads the punches of the clock now. The message gives the number of punches received and how many are new, for example Punches received: 48 (48 new). |
| Set time | Sets the clock to the date and time of the computer. |
| Supervisors | Sends to the clock the cards of the employees of its branch marked Supervisor (authorisations). |
Add a clock opens an empty clock.
The clock settings
| Field | What it does |
|---|---|
| Branch | The branch of the clock (New branch… to type a new number). |
| Location | Where the clock is, for example Front entrance, Warehouse or Bakery (the departments are suggested). It tells the clocks of one branch apart in the lists and in Today's punches. It has nothing to do with the hours: they are always calculated with each employee's own schedule. |
| Description | Optional: more about the clock, for example Tranz 380 near the time cards. |
| Automatic collection | The clock is read automatically at the times of Settings. |
| Serial port | The COM port of the cable. Ports not found on this computer are marked not found. Other port… lets you type a name that is not in the list, for example COM33. The state beside it shows Connected, Not found on this computer or Cannot check; Check again looks at the ports again. |
| Speed (baud) | 300 to 19200. Tranz 380: 2400. |
| Parity | Even, Odd or None. Tranz 380: Even. |
| Data bits | 7 or 8. Tranz 380: 7. |
| Stop bits | 1, 1.5 or 2. Tranz 380: 1. |
| Flow control | None, Hardware or Software. Usually None. |
| Delay between packets (ms) | A short wait between the messages exchanged with the clock. Default 100. |
A new clock starts with the Tranz 380 settings: COM1, 2400 baud, Even parity, 7 data bits, 1 stop bit, no flow control, 100 ms, automatic collection on.
How to add a clock
- Plug the clock's cable (or its USB adapter) into the computer.
- In the menu, click Clocks, then Add a clock.
- Choose the Branch and type its Location.
- Choose the Serial port: it should show Connected.
- Leave the Tranz 380 settings as they are, then click Save.
- Back in the list, click Collect to test.
How to collect the punches now
- In the menu, click Clocks.
- Click Collect on the line of the clock.
- Wait for the message: the clock is tried up to 3 times, 12 seconds apart, before Could not communicate with the clock is shown.
The punches go to the raw punches and to a .dat file in the clock archive folder (Settings). If a shared punches file is set, they are also added to it. Then calculate the hours of those days.
How the automatic collection works
The clocks with Automatic collection are read at the times listed in Settings > Automatic collection (for example 06:00, 22:00), as long as PunchPlus Web is running on this computer. If Then calculate the previous day's hours is checked, the hours of the day before are calculated right after each collection.
Set the clock time and send the supervisors
- Click Set time after a change to daylight saving time, or when the clock's time is wrong.
- Click Supervisors after adding or removing a supervisor in the employee files.
Both show Command sent to the clock. when they work.
When the clock does not answer
- Check that the Port status is Connected. If it is Not found, the cable or the USB adapter is unplugged, or it got another COM number: open the clock and choose the right port.
- Check the cable at both ends and that the clock is on.
- Check that no other program (for example WinPoll) uses the same port at the same time.